Chapter 16 Firmware Revision History
513
Firmware Version 3/4.31.37
Fix: Issue with stopping and then restarting a load when the Deliver Type (Preset Level)
was set to something different than the Meter Type (Meter Level) was set to.
Example: if Meter Type was set to VOL PULSES but Deliver Type was set to MASS. The
MultiLoad could accidently set a load to complete
before reaching the target preset amount because the gross volume delivered was equal
to or greater than the (preset_amount - final_volume_trip).
This would only occur when prematurely stopping the load, and then attempting to
restart it.
Fix: The issue mentioned above could also affect line flush functionality.
Removed: Email authentication functionality (temporarily).
Made some enhancements to the email state machine to improve performance.
Increased serial printer handshake timeout (CTS line) from 5 seconds to 30 seconds.
02/28/2017 TF
Fix: Purge routines for message/audit/trace logs not working.
03/24/2017 TF
Firmware version increased to x.31.34
Note: some of the changes below were implemented before the bump of the firmware version,
but were not incorporated into the x.31.33 release
03/01/2017 MSH
Fix: Bug in transaction export reports with standalone prompts.
03/17/2017 MSH
Fix: (UAP Only) Bug in picklist filter. Even when UAP was configured correctly the driver
might still see all customer, carrier, and/or accounts that were in the database. Instead
of a filtered list based on previous selections.
03/24/2017 MSH
Add Custom Logic support for additional analog inputs (SCS I/O board only).
03/24/2017 TF
Fix: Needed to increase max flow rates for the meter factors to support the new increased
flow rates of up to 25000.
Fix: 1980s 53B API Table was not calculating a corrected density.
03/28/2017 TF
Fix: Typo in German BOL.
Decreased the Alarm Low Pressure minimum value to support negative pressure. The mininum
value is now -20.00.
03/28/2017 MSH
Fix: Display of VCF overwrites "Corrected Density" label on component status screen.
Fix: Some network parameters (eg email) not included when saving configuration to SD
card.
05/10/2017 TF
Increase firmware version to x.31.35
Fix: Issue with printing corrected density in Alibilog for single component arms.
The MultiLoad failed to print the corrected density to the Alibilog if the arm only
had one component configured.
Fix: Issue with printing component details in the Alibilog, when the amount of
information to be printed exceeded 80 characters. Now the MultiLoad will wrap the
text to the next line. This would only occur if any of the 2004 X API tables were
used and a pressure sensor was enabled.