Chapter 16 Firmware Revision History
515
Firmware Version 3/4.31.37
Fix: MultiLoad incorrectly assigned the control valve logic to an FCM analog output when
the control valve type was set to NONE, which would throw an erroneous error message if
an additive output was assigned to the same analog output.
09/15/2017 TF
Added the ability adjust the low flow targets using the blend adjustment logic.
NOTE: If someone is upgrading, and the blend adj volume parameter is set to a value
that is less than the low flow volume, the blend adj volume parameter may need to be
adjusted to achieve the same behavior before the upgrade.
09/25/2017 TF
Fix: MultiLoad not saving the Require Authentication alarm parameters to the
configuration file.
Fix: Enumerations not being returned for FLOW_CONTROL_VALVE_TYPE. This only affects MM+,
or any other host system attempting to download the prompts.
09/26/2017 TF
Change "Legal For Trade" message for external presets in the load_screen
Update load_screen to display more than 7 characters for the "Total Delivered" field.
The maximum number of characters is now calculated based on the length of the label,
which is different for each translation. At a minimum it will display 9 characters.
2017/09/27 TF
Fix: (SIMULATION MODE ONLY) Low flow restart functionality while in simulation mode.
Functionality with real hardware was/is working properly.
Improved the bootup time if SD card is not present.
Increased the max value to 65535 seconds for divert time, divert restart time, diverts
tabilization time, and divert alarm time parameters.