E4 Series
Maintenance Manual
Power Plant
Page 300
E4.08.04
Rev. 29
71 - Maintenance Procedures
01-Jul-2020
d) Replace the connector for Alternator E4A-91-400-000
Pos.
Partnumber
Description
Qty.
1
E4A-90-R21-000-
000
Assy Repair Kit Cable
1
2
-
Cutter
1
3
-
Hot Air Gun
1
4
-
Crimp Tool for
TE (Tyco)D-436-37 crimp
1
Detail Steps/Work Items
Key Items/References
(1)
Remove the black backsheel.
(2)
Cut off the connector G2/GEN as
near as possible to the connector
housing.
(3)
Remove the insulation of the
remaining harness and repair kit
cable.
Backshell
Remaining Harness
5 mm (+/-2)