E4 Series
Maintenance Manual
Power Plant
Page 302
E4.08.04
Rev. 29
71 - Maintenance Procedures
01-Jul-2020
Detail Steps/Work Items
Key Items/References
long enough to be a cover for the
inline crimp and the black expando.
(8)
Do a check of the connection
between pins.
Use a Multimeter.
Connector
Pin
Connector
Pin
X1/2
4
G2/GEN
1
(9)
Attach the repair kit cable with the
cable ties PLT1M-M30 and PLT4S-
M30.