Power Plant
E4.08.04
Rev. 29
Page 303
71 -Maintenance Procedures
01-Jul-2020
e) Replace the connector for Alternator E4A-91-000-000
Pos.
Partnumber
Description
Qty.
1
E4A-90-R22-000-000
Assy Repair Kit Cable
1
2
-
Cutter
1
3
-
Hot Air Gun
1
4
-
Crimp Tool for
TE (Tyco)D-436-37 crimp
1
Detail Steps/Work Items
Key Items/References
(1)
Cut off the damaged part of the
solder sleeve at the engine
harness.
Do not use the worn connector for
repair.
(2)
Remove approx. 50 mm of black
insulation from the remaining
harness.
Solder Sleeve
50 mm (+5)