Power Plant
Page 308
E4.08.04
Rev. 29
71 - Maintenance Procedures
01-Jul-2020
Detail Steps/Work Items
Key Items/References
(7)
Remove the remaining shielding.
Remove the single wire insulation
for the two wires.
(8)
Put the blue isolation sleeve of the
inline crimp D-436-37 over the
single wire of the engine harness.
Put the splice crimp at the end of
each single wire of the repair kit
cable.
Requirements for crimping tool For crimp D-436-37 by
Tyco (TE Connectivity):
Manufacturer
Manufacturer
Part No.
Mil. Standard
No.
Raychem
AD-1377
M2250/37-01
(9)
Use the splice crimp D-436-37 to
connect the single wires of the
engine harness and the repair kit
cable.
Make sure that the pin connection
between ECU PWR and FMU is
correct. Use a Multimeter.
Connector
Pin
Connector
Pin
ECU PWR
V
FMU/Y94
2
ECU PWR
E
FMU/Y94
1
5 mm (+/-1)
Gasket
Crimp