71 - Maintenance Procedures
Remove the remaining shielding.
Remove the single wire insulation
for the two wires.
Put the blue isolation sleeve of the
inline crimp D-436-37 over the
single wire of the engine harness.
Put the splice crimp at the end of
each single wire of the repair kit
cable.
Requirements for crimping tool For crimp D-436-37 by
Tyco (TE Connectivity):
Use the splice crimp D-436-37 to
connect the single wires of the
engine harness and the repair kit
cable.
Make sure that the pin connection
between ECU PWR and FMU is
correct. Use a Multimeter.