"Removing the fan cage" on page 74.
Release all HDD modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD module" on page
149.
CAUTION
The HDD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page
146.
Removing the defective 10x 3.5-inch HDD backplane
If applicable, remove the internal RAID riser module, see "Removing the
internal RAID riser module" on page
273.
Disconnect all cables from the HDD backplane.
Figure 63: Removing the 10x 3.5-inch HDD backplane
Release the eight screws (see circles).
T
ake out the HDD backplane at a slight angle.
Hard disk drive (HDD) / solid state disk (SSD)