100 Upgrade and Maintenance Manual
RX300 S8
Basic software procedures
Ê If LAN teaming has been active, you will need to restore the configuration
using the LAN driver utility after replacing the system board.
I For details, refer to the relevant LAN driver manual.
5.2.18 Switching off the ID indicator
Press the ID button on the front panel, or use the iRMC web frontend or
ServerView Operations Manager to switch off the ID indicator after the
maintenance task has been concluded successfully.
I For further information, refer to section "Locating the defective server" on
page 51 or to the "ServerView Suite Local Service Concept (LSC)" and
"Integrated Remote Management Controller" user guides.
Using the ID button on the front panel
Ê Press the ID button on the front panel to switch off the ID indicators.
Using the iRMC web frontend
Ê Enter the ServerView iRMC web frontend.
Ê Under System Overview, click Identify LED Off to switch off the ID indicators.
Using ServerView Operations Manager
Ê In ServerView Operations Manager Single System View and press the Locate
button in the title bar to switch off the ID indicator.
5.2.19 Performing a fan test after replacing a defective fan
After replacing a defective system fan or power supply unit containing a
defective fan, the fan error indicators will stay lit until the next fan test. By
default, a fan test is automatically started every 24 hours. The first automatic fan
test being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX300 S8 Specifications

General IconGeneral
MemoryUp to 768 GB DDR3
Form Factor2U rack server
Remote ManagementiRMC S4 (Integrated Remote Management Controller)
ChipsetIntel C602
ProcessorIntel Xeon E5-2600 v2 product family
StorageUp to 16 x 2.5" or 8 x 3.5" drives
RAIDRAID 0, 1, 5, 6, 10, 50, 60
Network4 x Gigabit Ethernet ports
Expansion Slots6 x PCIe 3.0 slots
Operating System SupportWindows Server, Red Hat, SUSE, VMware
Memory TypeDDR3 RDIMM/LRDIMM
Power SupplyHot-plug redundant power supply units