EasyManua.ls Logo

Fujitsu PRIMERGY RX300 S8

Fujitsu PRIMERGY RX300 S8
502 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX300 S8
Upgrade and Maintenance Manual 439
System board and components
14.6.4 Concluding steps
Ê Reconnect all cables to the system board. For a complete cabling overview,
please refer to section "List of used cables" on page 465.
Ê Reinstall all remaining system board components as shown in the related
sections:
SAS RAID controller: see section "Installing the SAS RAID controller" on
page 190
onboard SAS enabling key: see section "Installing the onboard SAS
enabling key" on page 425
Heat sinks: see section "Installing processor heat sinks" on page 286
Memory modules: see section "Installing a memory module" on
page 253
I Install all memory modules into their original slots.
Expansion cards: see section "Installing expansion cards" on page 182
I Install all expansion cards into their original slots.
UFM: install the UFM spacer to the system board and install the UFM see
section "Installing the UFM" on page 403
TPM (if applicable): see section "Installing the TPM" on page 413
Ê "Installing the power backplane" on page 118
Ê "Installing the fan box" on page 164
Ê "Reassembling" on page 63
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
corresponding BIOS Setup Utility Reference Manual.
Ê Reconnect all external cables.
Ê "Connecting the server to the power source" on page 69
Ê "Updating or recovering the system board BIOS and iRMC" on page 80
Ê "Verifying system information backup / restore" on page 83
Ê "Verifying the system time settings" on page 91