RX300 S8
Upgrade and Maintenance Manual 439
System board and components
14.6.4 Concluding steps
Ê Reconnect all cables to the system board. For a complete cabling overview,
please refer to section "List of used cables" on page 465.
Ê Reinstall all remaining system board components as shown in the related
sections:
– SAS RAID controller: see section "Installing the SAS RAID controller" on
page 190
– onboard SAS enabling key: see section "Installing the onboard SAS
enabling key" on page 425
– Heat sinks: see section "Installing processor heat sinks" on page 286
– Memory modules: see section "Installing a memory module" on
page 253
I Install all memory modules into their original slots.
– Expansion cards: see section "Installing expansion cards" on page 182
I Install all expansion cards into their original slots.
– UFM: install the UFM spacer to the system board and install the UFM see
section "Installing the UFM" on page 403
– TPM (if applicable): see section "Installing the TPM" on page 413
Ê "Installing the power backplane" on page 118
Ê "Installing the fan box" on page 164
Ê "Reassembling" on page 63
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
corresponding BIOS Setup Utility Reference Manual.
Ê Reconnect all external cables.
Ê "Connecting the server to the power source" on page 69
Ê "Updating or recovering the system board BIOS and iRMC" on page 80
Ê "Verifying system information backup / restore" on page 83
Ê "Verifying the system time settings" on page 91