434 Upgrade and Maintenance Manual
RX300 S8
System board and components
14.6.2 Removing the defective system board
Ê Remove all cables from the system board.
Ê Remove the following components from the system board as shown in the
related sections:
– Heat sink: see section "Removing processor heat sinks" on page 291
I Leave the processor on the defective board for now.
– Memory modules: see section "Removing memory modules" on
page 256
I Ensure to take note of the memory modules’ mounting positions
for reassembly.
– Expansion cards: see section "Removing expansion cards" on page 185
I Ensure to take note of the controllers’ mounting positions and
cable connections for reassembly.
– UFM: see section "Removing the UFM" on page 406
– onboard SAS enabling key: see section "Removing the onboard SAS
enabling key" on page 428
– SAS RAID controller: see section "Removing the SAS RAID controller"
on page 193

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX300 S8 Specifications

General IconGeneral
MemoryUp to 768 GB DDR3
Form Factor2U rack server
Remote ManagementiRMC S4 (Integrated Remote Management Controller)
ChipsetIntel C602
ProcessorIntel Xeon E5-2600 v2 product family
StorageUp to 16 x 2.5" or 8 x 3.5" drives
RAIDRAID 0, 1, 5, 6, 10, 50, 60
Network4 x Gigabit Ethernet ports
Expansion Slots6 x PCIe 3.0 slots
Operating System SupportWindows Server, Red Hat, SUSE, VMware
Memory TypeDDR3 RDIMM/LRDIMM
Power SupplyHot-plug redundant power supply units

Related product manuals