EasyManua.ls Logo

Fujitsu PRIMERGY RX300 S8

Fujitsu PRIMERGY RX300 S8
502 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX300 S8
Upgrade and Maintenance Manual 263
Processors
11.2 Installing processors
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.1 Preliminary steps
Ê "Disabling BitLocker functionality" on page 73
Ê "Disabling SVOM boot watchdog functionality" on page 74
Ê "Shutting down the server" on page 54
Ê "Disconnecting power cords" on page 54
Ê "Getting access to the component" on page 57.c
11.2.2 Installing the processor
I This description applies to the following procedures:
Installing the second CPU in a mono-processor configuration
Transfering a CPU after replacing the system board (see section
"Swapping processors" on page 438)
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tool: Phillips PH2 / (+) No. 2 screw driver

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S8