214 Upgrade and Maintenance Manual
RX300 S8
Expansion cards and backup units
9.6.2.6 Concluding steps
Ê "Reassembling" on page 63
Ê "Connecting the server to the power source" on page 69
Ê "Switching on the server" on page 71
Ê If applicable, "Updating RAID controller firmware" on page 84.
Ê "Enabling SVOM boot watchdog functionality" on page 89
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 8 hours before the BBU will initiate a
recalibration cycle.
Ê Enter the ServerView RAID Manager and check the current BBU status.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
Ê If the BBU is shown as bad or defective, do not power off the server for at
least 8 hours to allow the charge and calibration cycles to finish.
Ê If the BBU status does not change after 8 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.