RX300 S8
Upgrade and Maintenance Manual 203
Expansion cards and backup units
9.5.2.6 Concluding software tasks
If the Modular LAN controller is to be used as a shared LAN interface, please
proceed as follows:
Ê Ensure that the NCSI cable has been connected to the Modular LAN
controller and the system board as described in sections "Connecting the
NCSI sideband cable to the Modular LAN controller" on page 198 and
"Connecting the NCSI sideband cable to the system board" on page 201.
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under iRMC LAN Parameters Configuration set the Management LAN Port
setting to Shared 2.
Ê Save your changes and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.