Upgrade and Maintenance Manual 81
Basic software procedures
5.2.1.1 Updating or recovering the system board BIOS
BIOS flash procedure
I For the Japanese market, follow the instructions provided separately.
Ê Perform the BIOS flash procedure as described in your server’s "BIOS
Setup Utility" reference manual.
BIOS recovery procedure
I For the Japanese market, follow the instructions provided separately.
Ê Perform the BIOS recovery procedure as described in your server’s "BIOS
Setup Utility" reference manual.
5.2.1.2 Updating or recovering the iRMC
iRMC flash procedure
I For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Connect the USB stick to the USB port.
I Ensure that only the USB device with the iRMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Restart the server.
Ê The system will detect the USB stick.
I If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose one of the following options from the update tool menu to start the
iRMC update process:
Normal Choose this option to update an existing system board.