RX300 S8
Upgrade and Maintenance Manual 83
Basic software procedures
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê Shut down the server by pressing the power On / Off button.
Ê Disconnect the server from the mains to exit the iRMC recovery state.
5.2.2 Verifying system information backup / restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section "Viewing and clearing the System Event Log (SEL)" on
page 92).
After replacing the system board
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 92 to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Restore successful
After replacing the Chassis ID EPROM
I In case of the PRIMERGY RX300 S8 server, the Chassis ID EPROM is
integrated on the front panel board.
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 92 to verify whether a backup copy of the
system board settings has been transferred to the Chassis ID EPROM:

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX300 S8 Specifications

General IconGeneral
MemoryUp to 768 GB DDR3
Form Factor2U rack server
Remote ManagementiRMC S4 (Integrated Remote Management Controller)
ChipsetIntel C602
ProcessorIntel Xeon E5-2600 v2 product family
StorageUp to 16 x 2.5" or 8 x 3.5" drives
RAIDRAID 0, 1, 5, 6, 10, 50, 60
Network4 x Gigabit Ethernet ports
Expansion Slots6 x PCIe 3.0 slots
Operating System SupportWindows Server, Red Hat, SUSE, VMware
Memory TypeDDR3 RDIMM/LRDIMM
Power SupplyHot-plug redundant power supply units

Related product manuals