RX300 S8
Upgrade and Maintenance Manual 501
Appendix
Ê "Shutting down the server" on page 54
Ê "Disconnecting power cords" on page 54
Ê Take the system down to its minimum startup configuration.
Ê "Connecting the server to the power source" on page 69
Ê Connect a keyboard, mouse and display to the server.
Ê "Switching on the server" on page 71
V CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
Component Notes
System board no TPM, UFM or expansion cards installed
CPU with CPU heat sink
1 memory module installed in DIMM slot 1A
Front panel module without connected front LAN module
Power supply unit
Table 11: Minimum startup configuration - components
Cable Notes
Front panel cable
Power cable
Table 12: Minimum startup configuration - cables