365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 2
NTP-007
Establish Restoration Protection Access in
Point-to-Point Network
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 network element to prevent electrostatic
discharge damage to sensitive components. See "Electrostatic
Discharge (ESD) Considerations" in Trouble Clearing: TAD-100.
At the local FT-2000 end terminal, obtain the
circuit order instructions to establish restora-
tion protection access. Both FT-2000 end ter-
minals must be provisioned.
—
2. At the local FT-2000 end terminal (if required),
connect and condition the craft interface terminal
(CIT).
DLP-501
3. To verify the provisioning, obtain a report by selecting
CONFIGURATION-Retrieve-Protection-Line.
At the local FT-2000 end terminal, at the CIT,
select
CONFIGURATION-Set-Protection-Line
and Restoration Protection Access
set to Yes.
—
4. At the remote FT-2000 network element, repeat
Steps 1 through 3. This can be accomplished by
establishing a remote login.
DLP-524

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish