365-575-102 Circuit Order: NTP-008
Issue 8.0, July 2002 Page 5 of 12
Instruct the technician at the West node (or travel
to that location) to enter the
FAULT-Switch-Line:1E:Forced command
at the CIT for line 1E. This makes a forced switch
on line 1E and may cause traffic hits.
—
Figure 2 – Forced Switched Lines at the East Node and the West Node
4.
!
CAUTION:
A line forced switch will preempt extra traffic, if any, on the protection
tributaries.
Instruct the technician at the East node (or
travel to that location) to enter the
FAULT-Switch-Line:1W:Forced com-
mand at the CIT for line 1W. This makes a
forced switch on line 1W and may cause traf-
fic hits.
—
5. Refer to Figure 3 to help locate the OC-48 optical
fibers that can now be removed from the West
node (fibers connected to East node).
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
Line
1W
WEST
NODE
Line
1E
NEW
NODE
EAST
NODE
Other
Node(s)
Other
Node(s)
Line
1W
Line
1W
Line
1E
Line
1E
Line
1E
Line
1E
Line
1W
Line
1W
tpa 832676/01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish