NTP-009: Circuit Order 365-575-102
Page4of8 Issue8.0,July2002
Instruct the technician at the West Node (or
travel to that location) to enter the
FAULT-Switch-Line:1E:Forced com-
mand at the CIT. This makes a forced switch
on line 1E and may cause traffic hits.
—
Figure 2 – Forced Switched Lines at the East Node and the West Node
7. Instruct the technician at the East Node (or
travel to that location) to enter the
FAULT-Switch-Line:1W:Forced command
at the CIT. This makes a forced switch on line
1W and may cause traffic hits.
—
8.
NOTE:
Refer to Figure 3 to help locate the OC-48 optical fibers that can now be
removed at the Node To Be Deleted (fibers connected to the West
Node).
Remove the OC-48 optical fibers at the
Node To Be Deleted (line 1W) that con-
nected to the West Node.
—
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
Line
1W
WEST
NODE
Line
1E
EAST
NODE
Other
Node(s)
Other
Node(s)
Line
1W
Line
1W
Line
1E
Line
1E
Line
1E
Line
1E
Line
1W
Line
1W
tpa 832681/01
NODE
TO BE
DELETED