365-575-102 Circuit Order: NTP-012
Issue 8.0, July 2002 Page 3 of 6
5. Determine from the report if the OC-12 circuit
pack is already present in the slot associated
with an OC-12 circuit pack to be added. A circuit
pack is in the slot if OC-12 is indicated in the
Circuit Pack column of the report.
If circuit pack(s) is present in the slot(s), then
continue with Step 11.
If circuit pack(s) is not present in the slot(s),
then continue with Step 6.
If any circuit pack(s) other than OC12 is present
in the slot(s), remove the circuit pack(s), perform
a CONFIGURATION-Update command, and
continue with Step 6.
6. Remove the appropriate low-speed shelf cover. DLP-511
7. If necessary, remove the apparatus (circuit
pack) blank(s) from the slot(s) requiring new
circuit pack(s).
DLP-533
8.
NOTE:
OC-12 circuit pack requires Release 7.1 or later software.
Install OC-12 circuit pack(s) into the speci-
fied slot(s) of the low-speed shelf [with the
appropriate receive lightguide buildouts
(LBOs)] and then connect the optical fibers
per the circuit order.
DLP-514
9. Verify the FAULT LED on each OC-12 circuit
pack(s) goes off within 1 minute after the circuit
pack is installed.
—
10. Replace the shelf cover. DLP-511
11. Make the appropriate external
cross-connections at the lightguide
cross-connect panel or equivalent.
—
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish