NTP-012: Circuit Order 365-575-102
Page2of6 Issue8.0,July2002
NOTE:
This procedure may be performed after all installation wiring (fiber)
and testing of the Low Speed Shelf - System Controller have been
completed or on an in-service basis. Additional installation
information is contained in 365-575-115,
FT-2000 OC-48 Lightwave
System, Installation Manual
.
Obtain the circuit order instructions to add
OC-12 (T939A) circuit pack(s) and note the
assigned address(es). The address
requires a slot assignment.
—
2. If required, connect and condition the craft
interface terminal (CIT).
DLP-501
3.
NOTE:
For Releases 7.1 and later, the Alarm Level parameter must be
provisioned to NO whenever an unused OC-12 input is present.
If required, provision the OC-12 slot
parameter(s).
DLP-517
Supplemental Information: If an incoming
OC-12 LOS condition exists prior to setting the
Alarm Level to NO, this condition will not
disappear after the Alarm Level is set to NO.
Only subsequent conditions will be subdued (not
reported). The user may clear the condition by
temporarily providing a good input signal until
the condition clears or by reseating the OC-12
circuit pack. Only reseat the circuit pack if you
are sure there is no live traffic on the outgoing
fiber, otherwise service interruption will occur.
4. At the CIT, select
CONFIGURATION-Retrieve-Equipment,
then LS INTFC and execute to obtain an
Equipage and Version Report.
—
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO