NTP-013: Circuit Order 365-575-102
Page4of4 Issue8.0,July2002
Circuit Order: NTP-011---+---TAD-100
|---DLP-501
|---DLP-511
|---DLP-514
|---DLP-511
|---DLP-542
14. At the CIT, select CONFIGURA-
TION-Delete-Assignment-DCC to
remove the DCC assignment; and repeat
the CONFIGURATION-Delete-Assign-
ment-DCC command for each DCC chan-
nel to be removed.
DLP-542
15. After the rings are separated, it is possible that a
DSNE not reachable and/or NE status
communication failure condition(s) may be
generated. To clear this, assign a DSNE
(TAP-137) and AGNE (TAP-172) in the ring that
contains the alarms.
The OC-12 circuit pack(s) has been removed.
—
16. STOP! YOU HAVE COMPLETED THIS
PROCEDURE.
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO