NTP-014: Circuit Order 365-575-102
Page2of6 Issue8.0,July2002
2. Determine whether the identified Protection slot
is already equipped. At the CIT, select
CONFIGURATION-Retrieve-Equipment and
execute to obtain a report depicting how the
shelf is currently equipped.
3. From the report, is the required protection slot
equipped with an existing circuit pack?
If NO, then go to Step 12.
If YES, then continue with Step 4.
4. Is the slot already equipped with an optical
circuit pack?
If NO, then go to Step 8.
If YES, then continue with Step 5.
5. Are fibers already terminated on the OC-3/IS-3
circuit pack?
If NO, then it is available, go to Step 12.
If YES, then continue with Step 6.
6. Determine whether the slot already has
cross-connects defined. At the CIT, select the
CONFIGURATION-Retrieve-Crossconnect
-all command for this slot.
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO