EasyManua.ls Logo

Lucent Technologies FT-2000 OC-48 - Page 1058

Lucent Technologies FT-2000 OC-48
1578 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NTP-015: Circuit Order 365-575-102
Page6of6 Issue8.0,July2002
Circuit Order: NTP-015-----+-----Circuit Order : NTP-003
Circuit Order: NTP-010
Circuit Order: NTP-013---+---DLP-517
|----DLP-536
22. Change the service quad’s “Protection Mode”
from 0x1 to 1+1 in both the “from OC12” and
“from OC48” direction.
DLP-517
NOTE:
Changing the service quad’s “Protection Mode” clears the OC12 Mode
Conflict Alarm.
23. Enter the appropriate cross-connection(s) for
the protection quad.
DLP-536
24. Use CONFIGURATION-Retrieve-OC12
command to verify that the operating mode is
1+1 for the quad pair.
If Operating Mode is 1+1,thenSTOP! You
Have Completed This Procedure.
If Operating Mode is NOT 1+1, then
contact your next level of
Technical Support.
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO

Table of Contents