NTP-017: Circuit Order 365-575-102
Page2of6 Issue8.0,July2002
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 terminal to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.
From the instructions (work order), identify the quad
pair addresses of the “Service and Protection Links”
(1b and 3b),or(5b and 7b).
2. If required, connect and condition the craft
interface terminal (CIT).
DLP-501
3. At near-end Node A, use
FAULT-Retrieve-State command to obtain
a report that lists the current actual protection
Switch State.
If Service Quad (1b or 5b) Switch State
is active (rx:act),gotoStep7.
If Service Quad (1b or 5b) Switch State
is standby (rx:stby), then continue with
Step 4.
—
4. At the CIT, perform the
FAULT-Switch-OC12:slot:priority
command [whereas for the
slot
enter the
Protection slot (3b or 7b) that you wish to lock
out and for the
priority
enter or choose the
lockout priority].
You perform this command to (1) switch service
from the Protection quad (3b or 7b)tothe
Service quad (1b or 5b) for this near-end NE,
and (2) prevent further selection of the
Protection quad by this near-end NE.
NOTE:
Service will be switched unless there is an
existing
inhibit
request active.
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO