NTP-018: Circuit Order 365-575-102
Page2of4 Issue8.0,July2002
If OC-3 interface, use the CONFIGURATION-
Set-OC3 command to set one of the service
slots (1A, 2A, 3A, 4A, 5A, 6A, 7A, or 8A) for 1+
1 protection in the “from OC3” direction and 0x
1 protection in the “from OC48” direction.
NOTE:
The FT-2000 ADR Terminal does not
support mixed LAA10/LAA10B operation in
a 1+1 configuration. To configure a OC-3
low speed interface for 1+1 configuration,
any two adjacent low speed slots (for
example, 2A and 2B) MUST be equipped
withthesametypeOC3(1.3STD)circuit
pack, and not a mix of the two.
If OC-12 interface, use the CONFIGURATION-
Set-OC12 command to set one of the service
quads (1B or 5B) for 1+1protection in the “from
OC12” direction and 0x1protection in the “from
OC48 direction.
_
2.
NOTE:
Steps 2 and 3 reference the same tributary.
Use the CONFIGURATION-Enter-
Crossconnection command to provision an
add (or 1-way DRI) cross-connection from the
service slot/quad.
_
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO

Table of Contents

Questions and Answers: