NTP-004: Operation 365-575-102
Page2of6 Issue8.0,July2002
2.
NOTE:
The primary node normally carries traffic via a DRI cross-connection.
From the operation instructions, identify and
record the target identifier (TID) of the pri-
mary node.
—
3.
NOTE:
The secondary node carries traffic only if the primary node is unable to
carry traffic.
From the operation instructions, identify and
record the cross-connections to be deleted
at the secondary node.
—
4. If required, connect the craft interface terminal
(CIT) to the local FT-2000 network element and
condition it.
DLP-501
5. Establish a login to the secondary node. (To
remotely establish a login, refer to DLP-524.)
—
6. The cross-connection to be deleted at the secondary node is a 1-way
slot-to-tributary (add) cross-connection.
At the CIT, select
CONFIGURATION-Retrieve-Crossconnect
ion-STS3 (or STS1) and execute to obtain
an STS3 (or STS1) Cross-Connection Map
Report. Examples of these reports with a
description of the output parameters are
provided in Section 11 of this manual.
—
7. Compare the report with the operation
instructions and record any slot-to-tributary
(add) cross-connections to be deleted at the
secondary node.
—
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish