EasyManuals Logo

Lucent Technologies FT-2000 OC-48 User Manual

Lucent Technologies FT-2000 OC-48
1578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1093 background imageLoading...
Page #1093 background image
365-575-102 Operation:
Issue 8.0, July 2002 Page 1 of 2
NTP-005
Copy Software From One Network Element to
Another Network Element
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Overview: This procedure is used to copy the software in one
FT-2000 network element to another FT-2000 network element
through the data communications channel (DCC) residing in an OC-3
or OC-48 signal. All of the FT-2000 network elements must be
running Release 5.0 or later software. This procedure can be
accomplished while the FT-2000 ring is in service.
Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
NOTE:
Release 5 allows copying software over the OC-48 line. Release 6
allows copying software over either the OC-3 or OC-48 lines.
NOTE:
For a general description on using a personal computer in the
following procedure, refer to DLP-529.
If required, connect the craft interface termi-
nal (CIT) to the local FT-2000 network ele-
ment and condition it.
DLP-501
2.
NOTE:
The CIT user must have a "privileged" security level.
Log in to the CIT using the expert mode by
entering cit expert.
—

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish