NTP-009: Operation 365-575-102
Page 2 of 16 Issue 8.0, July 2002
5. For ring-2, verify that there are no active alarms or
status conditions by selecting the
FAULT-Retrieve-Alarms (and Status):All or by
pressing function key F9. Review the Active Alarms
and Status Report and clear any conditions before
continuing with this procedure. Refer to TAP-102 as
appropriate.
—
6. Verify that each node, of both ring-1 and ring-2, is
running the same release of software.
NOTE:
If it is determined that the software on one or
more NEs must be upgraded - then follow the
procedures specified in the software release
description associated with the particular software
release.
—
7. Verify that each node, for both ring-1 and ring-2, has a
unique TID. At the CIT connected to any NE within
ring-1, select CONFIGURATION-Retrieve-Map-
Network command (R6.0.0 and later) to obtain the
Network Map Report or select
CONFIGURATION-Retrieve-Map Ring command to
obtain the Ring Map Report for release 5 and earlier.
An example of these reports with a description of the
output parameters is provided in Section 11 of this
manual.
—
NOTE:
The NID is a provisionable parameter for releases prior to R6.0.0 of ADR.
Therefore, for these releases also verify that each node, for both ring-1 and
ring-2, has a unique NID.
8. At the CIT connected to any NE within ring-2, select
CONFIGURATION-Retrieve-Map-Network
command (R6.0.0 and later) to obtain the Network Map
Report or select CONFIGURATION-Retrieve- Map
Ring command to obtain the Ring Map Report for
release 5 and earlier.
DO ITEMS BELOW IN ORDER LISTED . . . . . . . . FOR DETAILS, GO TO