TAP-101: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
If YES, then go to TAP-102.
If NO, then continue with Step 8.
NOTE:
A series number S1:2 is the same series number as S1:4. The 2 and 4 refer to
minor changes within series 1.
8. Obtain a replacement circuit pack with the same or a higher series number
and install it in place of the circuit pack with the lighted FAULT LED. As
required, make the appropriate optical connections on the OC-3, IS-3, OC-12,
RCVR, TRMTR, or REGENR circuit pack(s).
Reference: DLP-514
9. Wait for the time indicated in Table A:
*Inserting an LNCTL circuit pack starts a mini reset that can take up to 10 minutes to complete. During this time, LEDs
on other circuit packs will be lighted due to software provisioning.
†When a TG3 circuit pack is first inserted, it will be switched out of service until it warms up. This can take as long as
5 minutes.
10. Is the FAULT LED off on the circuit pack just replaced?
If YES, then continue with Step 11.
If NO, then go to TAP-116.
11. Replace the shelf cover.
Reference: DLP-511
12. Are all LEDs off at the user panel except the PWR ON LED?
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then go to Trouble Clearing: IXL-001.
Table A - Mini Reset Waiting Times
CP Inserted Waiting Time
LNCTL * 10 minutes
OHCTL 5 minutes
TG3 †5 minutes
TOHCTL 5 minutes
All Others 35 seconds