365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 8
TAP-102
Clear Local Trouble When `USE CIT' LED Is Lighted
Overview: This procedure is used to clear the conditions listed in the Active Alarms
and Status Report in the order listed, from top to bottom, regardless of the indicated
alarm severity, date, or time. The craft interface terminal (CIT) is required for this
procedure.
1. Is the CIT conditioned and connected to the FT-2000 network element?
If YES, then continue with Step 2.
If NO, then complete DLP-501 and return to this procedure.
2. At the CIT, select FAULT-Retrieve-Alarm (and Status):All to obtain
an Active Alarms and Status Report.
NOTE:
The report shown below is an example that shows several entries. There may
be only one entry in the actual report.
3. Record the information in the Source Address and the Description col-
umns for the topmost entry in the Active Alarms and Status Report.
Lucent Technologies FT-2000 96-11-19 23:15:15 EST
M Retrieve-Alarm:All: COMPLD
/* Active Alarms and Status Report
=============================================================
Alarm Source Date Time Srv Description
Level Address Detected
=============================================================
CR ls-1-1a 05-19 23:15:41 SA DS3 INTFC removed
-------------------------------------------------------------
ABN tg-1-2 05-19 23:15:42 nsa sync reference manual switch
ABN tg-1-2 05-19 23:15:42 nsa sync reference lockout
-------------------------------------------------------------
NE ACTY line-1 05-19 23:15:42 nsa line auto switch
NE ACTY line-1-p1 05-19 23:15:42 nsa path AIS
*/