365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 2
TAP-108
Address Missing or Incorrect Response
Overview: You were sent here from another procedure because the FT-2000
Network Element responded in an unexpected manner. This unexpected response
was a missing or incorrect LED indication or CIT message.
1. Review, and keep in mind, the unexpected response that sent you to this TAP.
2. Was the unexpected response from an LED or from the CIT?
If from an LED, then continue with Step 3.
If from the CIT, then continue with Step 9.
3. At the CIT, select
FAULT-Test-LED and execute.
Response: All LEDs are lighted for 10 seconds, off for 10 seconds, then
they return to their normal condition.
4. Did the LED(s) of interest operate as indicated above?
If YES, then continue with Step 5.
If NO, then continue with Step 13.
NOTE:
The LED operation appears to be normal.
NOTE:
If you are using Release 6 or 7 software and if an Active Alarms and Status
Report (use FAULT-Retrieve-Alarms) shows OHCTL failure for both 1E and 1W
and if neither LED is lighted at the OHCTL circuit packs (1E and 1W), then the
problem appears to be the TOHCTL circuit pack.
5. Replace the TOHCTL circuit pack.
Reference: DLP-514
6. Is the same unexpected response still observed?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then continue with Step 7.
7. Return to the procedure that sent you here. If the same unexpected response
is observed again, contact the appropriate maintenance support organization
for further technical assistance.
8. STOP! YOU HAVE COMPLETED THIS PROCEDURE.