TAP-108: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
9. At the CIT, select FAULT-Reset and execute.
10. Wait 10 minutes for the Reset to complete. During this time the lighting of
LEDs and clicking of relays will be observed.
11. Return to the procedure that sent you here. If the same unexpected response
is observed again, contact the appropriate maintenance support organization
for further technical assistance.
12. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
13. Replace the circuit pack, user panel, or filter panel containing the LED(s) that
did not operate as indicated in Step 4.
Reference: For Circuit Packs: DLP-514
For Panels: Drawing ED-6G994-30 (E-Bay)
For Panels: Drawing ED-7G001-33 (D-Bay)
14. Return to the procedure that sent you here. If the same unexpected
response is observed again, contact the appropriate maintenance
support organization for further technical assistance.
15. STOP! YOU HAVE COMPLETED THIS PROCEDURE.