TAP-145: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
10. Are you responsible for maintaining the remote FT-2000 network
element(s) as well as the local FT-2000 network element?
If YES, then continue with Step 11.
If NO, then initiate a Trouble Report to the remote FT-2000 network ele-
ment (or source of failure) stating the incoming OC-48 invalid F
byte condition.
11. At the CIT, select FAULT-Retrieve-Network Alarms to obtain a Network
Alarms Report.
12. Establish a remote login to the network element appearing at the topmost posi-
tion in the Network Alarms Report. If a remote login is required and you need
additional help, refer to DLP-524.
13. At the CIT, select FAULT-Retrieve-Alarms to obtain an Active Alarms and
Status Report for that network element.
14. Repeat Steps 5 through 10, and 12 and 13 for each of the remaining network
elements listed in the Network Alarms Report from Step 11.
15. Has the incoming OC-48 invalid F byte condition cleared?
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then go to TAP-108 to clear the unexpected response.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish