365-575-102 Trouble Clearing: TAP-156
Issue 8.0, July 2002 Page 3 of 4
!
CAUTION:
Incorrectly provisioned source node TID and/or destination node TID can result
in a service outage under certain multiple failure conditions.
NOTE:
The DS3 path unequipped condition is due to one or more missing
cross-connections, including one at this network element. The condition can be
cleared by entering the missing cross-connection(s) or by deleting all of the
cross-connections associated with the path at all of the associated nodes.
18. Referring to office records, enter the missing cross-connection(s) or delete all
of the cross-connections associated with the path at all of the associated
nodes (DLP-536).
19. STOP! YOU HAVE COMPLETED THIS PROCEDURE.