TAP-158: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
7. Use the Provisioned and Operating columns in the report to identify the
slot pair that is not provisioned correctly (mismatched).
8. At the CIT, select CONFIGURATION-Set-OC3(or OC12) command to cor-
rectly provision the slot (must match).
Reference: DLP-517
9. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
10. For an LS INTFC slot to have an Operating Mode of "1+1," the two slots (A and
B) cannot be cross-connected to different tributaries in the applicable direction
of transmission. Depending upon the release you are using, at the CIT select
CONFIGURATION-Retrieve-Crossconnection-All to obtain a
Cross-Connection Map Report.
11. Use the Cross-Connection column in the report to locate the invalid
cross-connection(s).
12. At the CIT, select CONFIGURATION-Delete-Crossconnection command
to correct the invalid cross-connection(s).
13. STOP! YOU HAVE COMPLETED THIS PROCEDURE.