TAP-161: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
6. Use the TID identified in Step 5 to locate the FT-2000 network element. You
must dispatch to that location or ask for assistance from that location.
7. At the CIT, select CONFIGURATION-Retrieve-Alarms (and Status)
command to obtain an Active Alarms and Status Report.
8. Does the incoming DCC failure condition appear in the Description col-
umn of the report?
If YES, then go to TAP-120 (referenced from TAP-102).
If NO, then go to TAP-102 to clear any other condition(s) in the report
except for the circuit audit suspended condition.
9. If all previous steps have failed to clear the circuit audit suspended
condition, at the CIT, select FAULT-Reset and execute. During the reset
time, the miscellaneous discrete control points will be deactivated.
10. Wait 10 minutes or until the MJ LED is off at the user panel.
11. STOP! YOU HAVE COMPLETED THIS PROCEDURE.