365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 2
TAP-168
Clear ‘Incoming OC48 APS Default Byte’
NOTE:
This condition is normally a transient condition caused by a Reset in progress at
an upstream OC-48 source.
1. Wait 5 minutes or until the NE ACTY LED on the user panel goes off.
2. At the CIT, select FAULT-Retrieve-Alarms (and Status):All com-
mand and execute to obtain an Active Alarms and Status Report. An example
of this report with a description of the output parameters is provided in Section
11 of this manual.
3. Has the incoming OC48 APS default byte condition cleared?
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 4.
4. Issue a Trouble Report to the source of the incoming OC-48 signal stating the
incoming OC48 APS default byte condition.
5. STOP! YOU HAVE COMPLETED THIS PROCEDURE.