TAP-171: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
14. Are any conditions listed in the Descriptive column of the report?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then continue with Step 5.
15. At the CIT, select CONFIGURATION-Reset command and execute to reset
the network element.
16. Wait for the time indicated in Table A.
NOTE:
If the low-speed and/or the high-speed shelf cover is removed, you will see one
or more FAULT LEDs lighted.
17. At the CIT, select FAULT-Retrieve-Alarm (and status):All com-
mand and execute to obtain an Active Alarms and Status Report.
18. Are any conditions listed in the Descriptive column of the report?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then go to TAP-102.
19. STOP! YOU HAVE COMPLETED THIS PROCEDURE.