365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 2
TAP-173
Clear ‘X-Conn Provisioned But Not Est’
Overview: This condition arises from situations when hardware is not available,
such as a low-speed circuit pack not being physically inserted into a slot.
1. At the CIT, select FAULT-Retrieve-Alarms command and execute to
obtain an Active Alarms and Status Report.
2. From the report, determine the slot and/or tributary address of the cross-con-
nection.
3. If necessary, remove the low-speed shelf cover.
4. Verify that the circuit pack is inserted into the shelf per office records.
5. Obtain another Active Alarms and Status Report.
6. Is the x-conn provisioned but not est condition still shown in the
report?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then contact your next level of technical support.