TAP-172: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
6. Obtain another Active Alarms and Status Report. Is the NE status comm
failure condition still shown?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then continue with Step 7.
7. Is an inc.(OC48) DCC failure condition shown on the report?
If NO, then continue with Step 9.
If YES, then clear this condition first (refer to TAP-120) and return to this
procedure.
8. Wait 5 minutes after clearing the condition.
9. Obtain another Active Alarms and Status Report. Is the NE status comm
failure condition still shown?
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then continue with Step 10.
10. Is a trouble condition listed in the Descriptive column of the report?
If NO, then go to IXL-001 to start trouble clearing.
If YES, then go to TAP-102.
11. STOP! YOU HAVE COMPLETED THIS PROCEDURE.