365-575-102 Detailed Level Procedure: DLP-502
Issue 8.0, July 2002 Page 1 of 4
Perform Local Automatic Turnup Test
Overview: This acceptance procedure is used to verify the internal transmission
health of an out-of-service FT-2000 network element that was installed by someone
else. The FT-2000 network element must be equipped (circuit packs installed) per the
engineered configuration.
!
CAUTION:
Do not remove any circuit packs during testing because erroneous indications
can result.
1. Which FT-2000 network element are you testing?
If FT-2000 end terminal, then continue with Step 2.
If FT-2000 repeater bay/shelf, then continue with Step 4.
If FT-2000 add/drop-rings terminal, then continue with Step 6.
2. At the CIT, select FAULT-Test-Auto Turnup (use CONFIGURATION in
Release 1.1.1) with Mode: Local and All for the lines. This test can take up
to 10 minutes.
Response: Execution in progress (one dot appears about every
2 seconds).
NOTE:
The ‘Fault-Test-Auto Turnup-Local’ test occasionally indicts circuit packs in
random slots. Repeat the test with the indicted circuit pack in a different
slot. Unless the circuit pack fails in the other slot, it is highly unlikely that the
circuit pack is defective and it should not be returned.
NOTE:
A "g" is for good or successful test. A "-" is for not equipped, therefore not
tested. An "F" is for failed or unsuccessful test.
3. Does the report indicate "g" for good or "-" for not tested for each entry? See
Figure 1 for an end terminal example with only a service line. See Figure 2 for
an end terminal example with a service and protection line.
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then refer the problem to the group that installed the equipment.