365-575-102 Detailed Level Procedure: DLP-503
Issue 8.0, July 2002 Page 7 of 10
Figure 4 – Example of Test Auto Turnup Report - Cross-Connect Wir-
ing Test (Protection Line Only in a Point-to-Point Network)
Electrical Low Speed Cables
!
CAUTION:
Care must be used at the cross-connect bay because traffic is being carried on
the other low-speed cables that are not being tested.
21. At the low-speed cross-connect bay (that is, DSX-3, STSX-1, DACS III-2000,
etc.), loop back only the low-speed signals being tested. Do not use the
FAULT-Operate-Loopback command at the FT-2000 network element.
22. Is the NE ACTY LED lighted?
If YES, then refer to Trouble Clearing: IXL-001.
If NO, then continue with Step 23.
Lucent Technologies FT-2000 96-11-07 08:30:45 EST
M Test-Auto:P: COMPLD
/* Test Auto Turnup Report - Cross-Connect Wiring Test
=============================================================
Line P: ------------LS INTFC------------
1122334455667788
port ABABABABABABABAB
1 gggggFggFggggggg
2 gggggFgg-ggggggg
3 gggggFgg-ggggggg
*/
;