365-575-102 Detailed Level Procedure: DLP-519
Issue 8.0, July 2002 Page 5 of 6
17. Clean the connector on the transmit fiber and the OUT connector of the OC48
REGENR circuit pack with canned air or nontoxic gas.
Reference: DLP-510
18. Connect the transmit fiber to the OUT connector of the OC48 REGENR circuit
pack.
19. Select the receive fiber, remove the protector cap (if equipped), and store the
cap.
20. Clean the connector on the receive fiber and the buildout (if equipped) or the
IN connector of the OC48 REGENR circuit pack, using canned air or nontoxic
gas.
Reference: DLP-510
21. Connect the receive fiber to the line engineered buildout (if equipped) or the IN
connector of the OC48 REGENR circuit pack.
22. Repeat Steps 13 through 21 for the next OC48 REGENR circuit pack to have
the optical loopback removed.
23. Replace the shelf cover.
Reference: DLP-511
24. STOP! YOU HAVE COMPLETED THIS PROCEDURE.