365-575-102 DetailedLevelProcedure:
Issue 8.0, July 2002 Page 1 of 10
DLP-521
Establish Modem or
Datakit
®
Network Access
Overview: This procedure is used to access a distant FT-2000 network element
(NE) from a local craft interface terminal (CIT). Some of the more common CIT
access configurations are shown in Figures 1 through 4. Other configurations exist
with access gained through local company procedures. Once access is gained, the
FT-2000 network element responds to any CIT selections just as if you were
physically connected to it.
1. Are you using the public switched network (via modem) or the
Datakit
network?
If public switched network, then continue with Step 2.
If Datakit network, then continue with Step 25.
Quick Check for Compatible Modems (Both Locations)
2.
NOTE:
Modems at the CIT and FT-2000 NE locations must be compatible. Quick
check/setup of the modem parameters and connections are given in this
procedure for the FT-2000 NE location first, then for the CIT location.
NOTE:
The manufacturer's manuals may be referred to for specific instructions on
setting the modem parameters. For example, when using a
Penril
*
modem,
the speed conversion parameter must be set to off.
NOTE:
Additional information on using a modem for remote access is available in
Section 6, "Operations Interface." Also, refer to 365-575-115,
FT-2000
OC-48 Lightwave System, Releases 3, 4, and 5, Installation Manual
,orto
365-575-104,
FT-2000 OC-48 Lightwave System, Releases 1 and 2,
Installation Manual
.
* Registered trademark of Penril Corporation