DLP-527: Detailed Level Procedure 365-575-102
Page6of6 Issue8.0,July2002
31. Is there a need to replace another REGENR circuit pack?
If YES, then continue with Step 30.
If NO, then go to Step 35.
All Other Types
32. Identify the slot for the subject circuit pack. Remove the existing circuit pack
from the slot.
33. Install the replacement circuit pack.
34. At the CIT, select CONFIGURATION-Update and execute.
35. Wait the minimum time, indicated in Table B, for the circuit pack to reset.
* Inserting an LNCTL circuit pack starts a mini reset that can take up to 10 minutes to complete. During this time, LEDs on other
circuit packs will be lighted.
When a TG3 circuit pack is first inserted, it will be switched out of service until it warms up. This can take as long as 5
minutes. You can confirm that it is in the standby state by using the FAULT-Retrieve-State command for the TG slot.
36. Is the NE ACTY LED lighted at the user panel?
If YES, then go to Trouble Clearing: TAP-103.
If NO, then continue with Step 37.
37. Replace the shelf cover.
Reference: DLP-511
38. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
Table B - Mini Reset Waiting Times
CP Inserted Waiting Time
LNCTL * 10 minutes
OHCTL 5 minutes
TG3 5 minutes
TOHCTL 5 minutes
All Others 35 seconds