365-575-102 DetailedLevelProcedure:
Issue 8.0, July 2002 Page 1 of 2
DLP-530
Test Miscellaneous Discrete Telemetry
Overview: This procedure tests the user settable miscellaneous discrete
environmental (input) points and control (output) points.
1. Contact the remote operations center and request their help to observe the
environmental points and to activate the control points during this test.
2. At the remote operations center, disable, if desired, the alarm threshold level
for the points being tested.
3. Operate the first external device connected to the FT-2000 network element in
such a way as to cause a closed contact to appear at the network element
environmental input.
NOTE:
When an external device connected to the FT-2000 network element
causes a contact closure to appear as an environmental input to the
network element, a corresponding environmental point is activated at the
remote operations center.
4. Was the corresponding environmental point activated at the remote operations
center?
If YES, then continue with Step 5.
If NO, then report the trouble to the installation personnel.
5. Operate the first external device connected to the FT-2000 network element in
such a way as to cause an open contact to appear at the network element
environmental input.
6. Was the corresponding environmental point deactivated at the remote
operations center?
If YES, then continue with Step 7.
If NO, then report the trouble to the installation personnel.
7. Repeat Steps 3 through 6 for any remaining environmental points to be tested.