365-575-102 DetailedLevelProcedure:
Issue 8.0, July 2002 Page 1 of 2
DLP-547
Provision OC12 Slot for 1-Way Drop Service
Overview:
1. Determine the OC12 slot address from the work order (engineering
instructions).
2. At the CIT, select CONFIGURATION-Retrieve-Crossconnection
command and determine what type of cross-connection(s) (if any) is already at
that slot.
3. Is the OC12 slot cross-connected for a 1-way drop?
If NO, then continue with Step 4.
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
4. At the CIT, select CONFIGURATION-Set-OC12 command and provision the
Alarm Level to NO to prevent the reporting or alarming of any future condition.
5. At the CIT, select CONFIGURATION-Retrieve-OC12 command and verify
the Alarm Level is provisioned correctly.
Supplemental Information: If an incoming OC12 LOS condition ex-
ists prior to setting the Alarm Level to NO, this condition will not disap-
pear after the Alarm Level is set to NO. Only subsequent conditions will
be subdued (not reported). The user may clear the condition by tempo-
rarily providing a good input signal until the condition clears or by reseat-
ing the OC12 circuit pack. Only reseat the circuit pack if you are sure
there is no live traffic on the outgoing fiber, otherwise service interruption
will occur.
6. STOP! YOU HAVE COMPLETED THIS PROCEDURE.