Administration and Provisioning
8-50 Issue 8.0 July 2002
â– FAULT-Switch-Path-STS1: This input controls the state of an existing
1-way-DRI cross-connection. The state of the existing 1-way-DRI
cross-connection is switched by specifying the destination STS-1 tributary
and the protection switch priority (reset or manual).
An input requesting a DRI protection switch will be denied if the specified
destination STS-1 tributary is not involved in a 1-way-DRI cross-connection
or if the input is entered with a manual priority and the DRI protection
switch is in the automatic switch state. For more information about dual ring
interworking protection switching, refer to Volume I, Section 9,
"Maintenance Description."
â– FAULT-Switch-Path-STS3: This input controls the state of an existing
1-way-DRI cross-connection. The state of the existing 1-way-DRI
cross-connection is switched by specifying the destination STS-3 tributary
and the protection switch priority (reset or manual).
An input requesting a DRI protection switch will be denied if the specified
destination STS-3 tributary is not involved in a 1-way-DRI cross-connection
or if the input is entered with a manual priority and the DRI protection
switch is in the automatic switch state. For more information about dual ring
interworking protection switching, refer to Volume I, Section 9,
"Maintenance Description."