Administration and Provisioning
Issue 8.0 July 2002
8-131
At least 2 of the characters must be nonalphabetic
At least 1 of the characters must be symbolic (The \, @, #, ?,
$, or space not allowed) (the comma, :, ;, or _ not allowed)
The difference between upper and lower case is significant.
If ENTER is pressed, the system will default to the current
password.
The Re-enter Password parameter confirms the New Password
parameter. Reenter the exact characters that were entered for the
New Password parameter.
The User Privilege parameter sets the user's security level for
nonprivileged users to one of the following:
"Reports Only": User will be able to execute only the
Retrieve
, Set-Password, Operate-Alarm Cutoff, and
Test-LED inputs
"General": User will be able to execute all commands, except
Initialize-System
, Set-Far End Communications,
Set-Login, Set-Network Element, and Set-Security.
The user privilege parameter for a privileged user can only be set to
Privileged.
The Visitor parameter specifies whether the login will be changed to
a visitor login (Yes or No). A visitor login is a temporary login.
The Status parameter enables or disables the login. The status
parameter for a privileged user can only be set to Enabled.
SECURITY-Set-Login-Delete (TL1 = DLT-USER-SECU): This input
deletes a nonprivileged login. If the login is active at the time this command
is executed, the user is immediately logged off the system.
The Login parameter selects the login that is to be deleted. (The
Retrieve-Login input will list login IDs.)

Table of Contents